IBM服务器技术资料盘点
Device is a Hard disk
Channel : 1
SCSI ID : 0
PFA (Yes/No) : No
State : Ready (RDY)
Size (in MB)/(in sectors): 34715/71096368
Device ID : IBM-ESXSST336732B84G3ET0YAHS
FRU part number : 06P5778
Command completed successfully.
4.drivever--这个命令列出物理驱动器的vendor ID,firmware version和serial number。
命令格式 :IPSSEND DRIVEVER controller channel sid
l controller指的是raid控制器的id号(1-12)
l channel 指的是scsi通道(1-4)
l sid指scsi id号(0-15)
Ipssend drivever 1 1 0
显示如下:
Found 1 IBM ServeRAID controller(s).
SCSI Inquiry DCDB has been initiated for controller 1...
Device Type : Hard disk
Channel : 1
SCSI ID : 0
Vendor : IBM-ESXS
Revision Level : B84G
Serial Number : 3ET0YAHS
Command completed successfully.
5.getconfig--这个命令会列出关于controller,logical drive以及physical的相关信息
命令格式 :IPSSEND GETCONFIG controller AD/LD/PD/AL
controller指的是raid控制器的id号(1-12)
l AD显示控制器信息
l LD 显示逻辑驱动器的信息
l PD显示物理设备的信息
l AL显示以上的所有信息
举例:(默认controller 为 1)
ipssend getconfig 1 al
6.setconfig--这个命令改变控制器的配置,如恢复出场默认值,从硬盘拷贝阵列信息
命令格式 :IPSSEND SETCONFIG controller DEFAULT/IMPORTDRIVE
举例:
把一个控制器恢复成出场设置:
ipssend setconfig 1 default
从硬盘拷贝阵列信息:
ipssend setconfig 1 importdrive
7.scandrives--扫描控制器上的所有硬盘
命令格式 :IPSSEND SCANDRIVES controller
l controller指的是raid控制器的id号(1-12)
用法:(假设controller为1)
ipssend scandrives 1
8.backup--备份阵列信息
命令格式:IPSSEND BACKUP controller filename
l controller指的是raid控制器的id号(1-12)
用法举例:
ipssend backup 1 backupfile
9.restore--还原备份过的阵列信息
命令格式:IPSSEND RESTORE controller filename
l controller指的是raid控制器的id号(1-12)
用法举例:
ipssend restore 1 backupfile
关于ibm的RAID卡降BIOS 的办法
这是IBM升级盘里的一个程序flashman.pro 的文件,要改动下面的程序才可以降RAID 的BIOS ,用IBM RAID的光盘是降不RAID 的BIOS 的.它的办法是首先下载4.84 BIOS 的升级
程序.4.84 BIOS/firmare 的升级盘. flashman.pro 的文件内容如下:
ServeRAID family firmware and BIOS download utility profile
Disk Release: 4.84.01
Format =
[------ BIOS -------][---- Firmware -----][------ Boot -------]
:Adapter Name,Image Name,Rev#,Dsk#,Image Name,Rev#,Dsk#,Image Name,Rev#,Dsk#,
Type:ServeRAID,A:\
Unknown Adapter
:?,raid.img,99,1,codeblk.cph,99,2,bootblk.cph,0.00.00,1,
Copperhead Adapter
:ServeRAID,raid.img,4.84.01,1,codeblk.cph,2.25.01,2,bootblk.cph,0.00.00,1,
ServeRAID on planar image (Navajo)
:ServeRAID1C1,raid.img,4.84.01,1,codeblk.nvj,2.88.13,2,bootblk.nvj,0.00.00,1,
Copperhead-Refresh Adapter
:ServeRAID II,raid.img,4.84.01,1,codeblk.rf,2.88.13,2,bootblk.rf,0.00.00,1,
Copperhead-Refresh on planer (Kiowa)
:ServeRAID2C2,raid.img,4.84.01,1,codeblk.rf,2.88.13,2,bootblk.rf,0.00.00,1,
Clarinet Adapter
:ServeRAID-3H,raid.img,7.84.01,1,codeblk.cln,7.84.01,1,bootblk.cln,0.00.00,1,
Clarinet-Lite Adapter (Oboe)
:ServeRAID-3L,raid.img,7.84.01,1,codeblk.cln,7.84.01,1,bootblk.cln,0.00.00,1,
Trombone Adapter
:ServeRAID-4H,raid.img,7.84.01,1,codeblk.trb,7.84.01,2,bootblk.trb,0.00.00,1,
Morpheus Adapter
:ServeRAID-4M,raid.img,7.84.01,1,codeblk.neo,7.84.01,1,bootblk.mor,0.00.00,1,
Morpheus-Lite Adapter
:ServeRAID-4L,raid.img,7.84.01,1,codeblk.neo,7.84.01,1,bootblk.mor,0.00.00,1,
Neo Adapter
:ServeRAID-4Mx,raid.img,7.84.01,1,codeblk.neo,7.84.01,1,bootblk.neo,4.84.01,1,
Neo-Lite Adapter
:ServeRAID-4Lx,raid.img,7.84.01,1,codeblk.neo,7.84.01,1,bootblk.neo,4.84.01,1,
这个办法是 把 4lx,raid.img,4.84.01,1(改为 7.84.01,1),codedblk,neo,4.84.01,1((改为 7.84.01,1)其他不变,当BIOS 升级时发现 6.10不够高升级为新的7.84的BIOS ,实际生成 4.84.这叫明升暗降.
重新启动以后,RAID卡会报错,这是正常的,CATL+1 进入 RAID 卡 再作一次初始化,
重齐就OK 了.
从网上当一个4.84的升级BIOS的盘来作.用记事本打开 flashman.pro 的文件,去改动它.
如果降了. BIOS 还作不了 RAID 定是 硬盘坏了,将硬盘背板的SCSI线接到主板SCSI接口上,CATL+A 扫描硬盘看看是否均匀通过, 也可能 部分OEM 硬盘作不了 RAID 太差了吧,就没有作 RAID 的必要了.当然有一个 原装的IBM 硬盘 作一个 RAID 0 是最好的验证了.
我就帮到这里了,关键看你们自己判断了.有为难题
再打我的电话. 我的RAID 光盘很多从 RAID 3.0
到7.10 应有竟有,缺什么来电话,可以免费技术