IBM认证 百分网手机站

IBM服务器技术资料盘点(2)

时间:2017-06-29 14:06:12 IBM认证 我要投稿

IBM服务器技术资料盘点

  Device is a Hard disk

  Channel : 1

  SCSI ID : 0

  PFA (Yes/No) : No

  State : Ready (RDY)

  Size (in MB)/(in sectors): 34715/71096368

  Device ID : IBM-ESXSST336732B84G3ET0YAHS

  FRU part number : 06P5778

  Command completed successfully.

  4.drivever--这个命令列出物理驱动器的vendor ID,firmware version和serial number。

  命令格式 :IPSSEND DRIVEVER controller channel sid

  l controller指的是raid控制器的id号(1-12)

  l channel 指的是scsi通道(1-4)

  l sid指scsi id号(0-15)

  Ipssend drivever 1 1 0

  显示如下:

  Found 1 IBM ServeRAID controller(s).

  SCSI Inquiry DCDB has been initiated for controller 1...

  Device Type : Hard disk

  Channel : 1

  SCSI ID : 0

  Vendor : IBM-ESXS

  Revision Level : B84G

  Serial Number : 3ET0YAHS

  Command completed successfully.

  5.getconfig--这个命令会列出关于controller,logical drive以及physical的相关信息

  命令格式 :IPSSEND GETCONFIG controller AD/LD/PD/AL

  controller指的是raid控制器的id号(1-12)

  l AD显示控制器信息

  l LD 显示逻辑驱动器的信息

  l PD显示物理设备的信息

  l AL显示以上的所有信息

  举例:(默认controller 为 1)

  ipssend getconfig 1 al

  6.setconfig--这个命令改变控制器的配置,如恢复出场默认值,从硬盘拷贝阵列信息

  命令格式 :IPSSEND SETCONFIG controller DEFAULT/IMPORTDRIVE

  举例:

  把一个控制器恢复成出场设置:

  ipssend setconfig 1 default

  从硬盘拷贝阵列信息:

  ipssend setconfig 1 importdrive

  7.scandrives--扫描控制器上的所有硬盘

  命令格式 :IPSSEND SCANDRIVES controller

  l controller指的是raid控制器的id号(1-12)

  用法:(假设controller为1)

  ipssend scandrives 1

  8.backup--备份阵列信息

  命令格式:IPSSEND BACKUP controller filename

  l controller指的是raid控制器的id号(1-12)

  用法举例:

  ipssend backup 1 backupfile

  9.restore--还原备份过的阵列信息

  命令格式:IPSSEND RESTORE controller filename

  l controller指的是raid控制器的id号(1-12)

  用法举例:

  ipssend restore 1 backupfile

  关于ibm的RAID卡降BIOS 的办法

  这是IBM升级盘里的一个程序flashman.pro 的文件,要改动下面的程序才可以降RAID 的BIOS ,用IBM RAID的光盘是降不RAID 的BIOS 的.它的办法是首先下载4.84 BIOS 的升级

  程序.4.84 BIOS/firmare 的升级盘. flashman.pro 的文件内容如下:

  ServeRAID family firmware and BIOS download utility profile

  Disk Release: 4.84.01

  Format =

  [------ BIOS -------][---- Firmware -----][------ Boot -------]

  :Adapter Name,Image Name,Rev#,Dsk#,Image Name,Rev#,Dsk#,Image Name,Rev#,Dsk#,

  Type:ServeRAID,A:\

  Unknown Adapter

  :?,raid.img,99,1,codeblk.cph,99,2,bootblk.cph,0.00.00,1,

  Copperhead Adapter

  :ServeRAID,raid.img,4.84.01,1,codeblk.cph,2.25.01,2,bootblk.cph,0.00.00,1,

  ServeRAID on planar image (Navajo)

  :ServeRAID1C1,raid.img,4.84.01,1,codeblk.nvj,2.88.13,2,bootblk.nvj,0.00.00,1,

  Copperhead-Refresh Adapter

  :ServeRAID II,raid.img,4.84.01,1,codeblk.rf,2.88.13,2,bootblk.rf,0.00.00,1,

  Copperhead-Refresh on planer (Kiowa)

  :ServeRAID2C2,raid.img,4.84.01,1,codeblk.rf,2.88.13,2,bootblk.rf,0.00.00,1,

  Clarinet Adapter

  :ServeRAID-3H,raid.img,7.84.01,1,codeblk.cln,7.84.01,1,bootblk.cln,0.00.00,1,

  Clarinet-Lite Adapter (Oboe)

  :ServeRAID-3L,raid.img,7.84.01,1,codeblk.cln,7.84.01,1,bootblk.cln,0.00.00,1,

  Trombone Adapter

  :ServeRAID-4H,raid.img,7.84.01,1,codeblk.trb,7.84.01,2,bootblk.trb,0.00.00,1,

  Morpheus Adapter

  :ServeRAID-4M,raid.img,7.84.01,1,codeblk.neo,7.84.01,1,bootblk.mor,0.00.00,1,

  Morpheus-Lite Adapter

  :ServeRAID-4L,raid.img,7.84.01,1,codeblk.neo,7.84.01,1,bootblk.mor,0.00.00,1,

  Neo Adapter

  :ServeRAID-4Mx,raid.img,7.84.01,1,codeblk.neo,7.84.01,1,bootblk.neo,4.84.01,1,

  Neo-Lite Adapter

  :ServeRAID-4Lx,raid.img,7.84.01,1,codeblk.neo,7.84.01,1,bootblk.neo,4.84.01,1,

  这个办法是 把 4lx,raid.img,4.84.01,1(改为 7.84.01,1),codedblk,neo,4.84.01,1((改为 7.84.01,1)其他不变,当BIOS 升级时发现 6.10不够高升级为新的7.84的BIOS ,实际生成 4.84.这叫明升暗降.

  重新启动以后,RAID卡会报错,这是正常的,CATL+1 进入 RAID 卡 再作一次初始化,

  重齐就OK 了.

  从网上当一个4.84的升级BIOS的盘来作.用记事本打开 flashman.pro 的文件,去改动它.

  如果降了. BIOS 还作不了 RAID 定是 硬盘坏了,将硬盘背板的SCSI线接到主板SCSI接口上,CATL+A 扫描硬盘看看是否均匀通过, 也可能 部分OEM 硬盘作不了 RAID 太差了吧,就没有作 RAID 的必要了.当然有一个 原装的IBM 硬盘 作一个 RAID 0 是最好的验证了.

  我就帮到这里了,关键看你们自己判断了.有为难题

  再打我的电话. 我的RAID 光盘很多从 RAID 3.0

  到7.10 应有竟有,缺什么来电话,可以免费技术